Appliance Testing Setup as per BEE

Manufacturers who produce or market appliances for the Indian market are required to submit their product samples to BEE or its designated testing agency. Spectro Automation undertakes testing for Appliances as per standard for appliances as per Industrial Standards. We conduct tests as per the guidelines for BEE Certifications. Our services will ensure that your product saves energy & thereby has the potential to save cost.
 
Appliance Testing Setup as per BEE

Frost Free Refrigerator Test Setup

Parameters to be Tested

1. Energy consumption
2. Volume measurement test (storage and gross)
3. Pull down test
4. Operating Temperature
5. Performance Test

Relevant standards with amendments: - IS 15750*
Respective BEE Schedule (Refer Latest Revision):- Schedule 1
Frost Free Refrigerator Test Setup
 
 
 
 
 
 
Tubular Fluorescent Lamp Testing
 
 
 
 
 
 

Tubular Fluorescent Lamp Testing

Parameters to be Tested
  • Visual examination and marking
  • Lamp & Cap dimension
  • Torsion test
  • IR measurement test
  • Burning test
  • Starting test
  • Lamp elect & Lumen characteristics
  • Colour characteristics
  • Lumen maintenance & life test (at 100, 2000 hrs)
  • Lumen maintenance& life test (at 3500)
Relevant standards with amendments: - IS 2418 (Part I) , (Part II), (Part III) and Part(IV) - 1977
Respective BEE Schedule (Refer Latest Revision):- Schedule 2

Air Conditioner Testing Equipments

We offer Air Conditioner Testing Equipments.

Parameters to be Tested:-
  • Cooling capacity
  • Power consumption
  • Max operating condition test.

Relevant standards with amendments: - IS 1391 Part 1 & Part 2
Respective BEE Schedule (Refer Latest Revision):- Schedule 3 And 3A
Air Conditioner Testing Equipments
 
 
 
 
 
 
Direct Cool Refrigerator Testing
 
 
 
 
 
 

Direct Cool Refrigerator Testing

Parameters to be Tested
  • Energy consumption
  • Volume measurement test (storage and gross)
  • Pull down test
Relevant standards with amendments: - AS/NZS 4474.1 and AS/NZS 4474.2/ IS1476*
Respective BEE Schedule (Refer Latest Revision):- Schedule 5

Distribution Transformer Test Setup

Parameters to be Tested:-
  • Parameters to be Tested
  • Measurement of winding resistance
  • Measurement of impedance voltage /
  • short circuit impedance and load loss
    (at 50% & 100%)
  • Measurement of No load loss and current
  • Temperature rise test
  • Total losses (at 50% & 100%)

Relevant standards with amendments: - IS 1180 (Part 1)& IS 2206 (part 2) ad IS 2500 part 1): 200
Respective BEE Schedule (Refer Latest Revision):- Schedule 4
Distribution Transformer Test Setup
 
 
 
 
 
 
Induction Motor Testing
 
 
 
 
 
 

Induction Motor Testing

Parameters to be Tested
  • Measurement of winding resistance
  • No load test at rated voltage and at different voltages to compute windage losses
  • Full load test
  • Efficiency at 75% and 100% load
  • Efficiency class (eff 1 or eff 2)
Relevant standards with amendments: - IS 12615:2011; IS 4029 -1967; IS 325 : 1996
Respective BEE Schedule (Refer Latest Revision):- Schedule 6

Agricultural Pump Sets

Parameters to be Tested:-
  • Nominal Volume rate of flow
  • Nominal Head
  • Overall Efficiency
  • Performance Curve
Relevant standards with amendments: -
IS 14220:1994
IS 8034 : 2002
IS 9079 : 2002
IS 11346: 2004
Respective BEE Schedule (Refer Latest Revision):- Schedule 7
Agricultural Pump Sets
 
 
 
 
 
 
Ceiling Fans Test Setup
 
 
 
 
 
 

Ceiling Fans Test Setup

Parameters to be Tested
  • Air delivery & service Value
  • Fan speed and power input
  • Sweep (mm)
Relevant standards with amendments: - IS 374 :1979*
Respective BEE Schedule (Refer Latest Revision):- Schedule 8

Liquefied Petroleum Gas Stoves

Parameters to be Tested:-
  • Thermal efficiency
Relevant standards with amendments: - IS 4246 : 2002
Respective BEE Schedule (Refer Latest Revision):- Schedule 9
 
 
Liquefied Petroleum Gas Stoves
 
 
 
 
 
 
Water Heaters/ Electric Geysers Test Setup
 
 
 
 
 
 

Water Heaters/ Electric Geysers Test Setup

Parameters to be Tested
  • Standing losses (kwh/24hrs/45C)
  • Input Capacity (liters)
Relevant standards with amendments: - Power IS 2082:1993; IS 302-2-21
Respective BEE Schedule (Refer Latest Revision):- Schedule 10

Colour Television Test Setup

Parameters to be Tested:-
  • Standby mode Power Consumption
  • On mode Power Consumption
  • Maximum Annual Power Consumption (kWh/yr)
Relevant standards with amendments: - IEC 62301 Ed. 1.0 for Standby Mode& IEC 62087 Ed. 2.0 for On Mode
Respective BEE Schedule (Refer Latest Revision):- Schedule 11
Colour Television Test Setup
 
 
 
 
 
 
Washing Machine Test Setup
 
 
 
 
 
 

Washing Machine Test Setup

Parameters to be Tested
  • Energy and Water consumption
  • Determination of Wash Performance
  • Water Extraction Efficiency
  • Rinsing efficiency
  • Protection against Electric Shock
  • Input
  • Temperature Rise Test
  • IR and Leakage Current at Operating temperatures
  • IR and Electric Strength
  • Endurance
Relevant standards with amendments: - IS 14155 & IEC 60456
Respective BEE Schedule (Refer Latest Revision):- Schedule 12

Energy Meter Calibration Bench Installation

We are engaged in installing energy meter calibration bench with the help of our proficient specialists who offer this service with utmost care. We install an advanced control panel on the wheels, which is also equipped with a pc and standard energy meter. These energy meters have voltage and current that would be connected in conjunction to the meter under test in order to sense the parameters. We also install an energy meter with accuracy class 0. 5 along with the pc to enhance us in communicating the derived parameters. The entire system is connected with the pc and scada software that helps in hosting and presenting the data.
Energy Meter Calibration Bench Installation
 
 
 
 
 
 
Refrigerator & Air Conditioner Performance Testing System
 
 
 
 
 
 

Refrigerator & Air Conditioner Performance Testing System

We offer qualitative range of service in installing Refrigerator & Air conditioner Performance Testing System. These Testing Systems are highly effective to understand the performance of the Refrigerator and Air Conditioner performance. We use advanced software that are highly efficient and gives accurate output. This service does not effect the performance of the products, in fact they are highly helpful to give required service when required to enhance the execution of the products. We also personalize these services as per the clients' requirement and offer them at highly effective price. Respective BEE Schedule (Refer Latest Revision)